Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev. CEFAC ; 25(5): e4423, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1514760

RESUMO

ABSTRACT Purpose: to assess the recognition of salty, sweet, and citrus tastes in complete denture wearers. Methods: the study included toothless individuals (experimental group) who had been using, for at least 3 months and at the most 5 years, acrylic resin removable bimaxillary complete dentures in good condition and with adequate maxillo-mandibular relationship. The same assessment was performed in the control group, which had 26 toothed individuals. Volunteers had no difficulties ingesting any type of food. Salty, sweet, and citrus tastes were assessed with filter paper strips soaked in such solutions and placed on the tongue dorsum. Assessments were performed in duplicate and in random order. Results: the percentage rate of errors was similar between the control (9.6±13.5%) and experimental groups (10.5±15.5%) (p=0.80). There was no difference in the frequency of correct perception of tastes between denture wearers and toothed individuals. Conclusion: individuals who wore acrylic resin removable bimaxillary complete dentures perceived salty, sweet, and citrus tastes like toothed individuals did.


RESUMO Objetivo: avaliar o reconhecimento dos sabores salgado, doce e cítrico em usuários de prótese dentária total. Métodos: foram incluídos indivíduos desdentados (grupo experimental) usuários de prótese total removível bimaxilar confeccionada em resina acrílica, com tempo mínimo de uso de três meses e máximo de cinco anos, em bom estado de conservação e com adequada relação maxilo-mandibular. Como grupo controle, a mesma avaliação foi realizada em 26 indivíduos dentados. Os voluntários não tinham dificuldade na ingestão de nenhum tipo de alimento. Os sabores salgado, doce e cítrico foram testados com fitas de papel filtro embebidas nas soluções e colocadas na parte dorsal da língua. As avaliações foram realizadas em duplicata e em ordem ao acaso. Resultados: a taxa percentual de erros foi igual entre os grupos controle (9,6±13,5%) e experimental (10,5±15,5%) (p=0,80). Não houve diferenças na frequência de percepção correta dos sabores entre indivíduos usuários de prótese e indivíduos dentados. Conclusão: usuários de prótese total removível bimaxilar confeccionada em resina acrílica têm a mesma percepção dos sabores salgado, doce e cítrico que indivíduos dentados.

2.
Braz. dent. j ; 28(3): 405-412, May-June 2017. graf
Artigo em Inglês | LILACS | ID: biblio-888641

RESUMO

Abstract Sjögren's syndrome (SS) is a systemic chronic autoimmune disorder affecting the lacrimal and salivary glands. SS may manifest as primary SS (pSS) or secondary SS (sSS), the latter occurring in the context of another autoimmune disorder. In both cases, the dry eyes and mouth affect the patient's quality of life. Late complications may include blindness, dental tissue destruction, oral candidiasis and lymphoma. This paper reports two cases of SS, each of them presenting unusual oral nodular lesion diagnosed as relapsed MALT lymphoma and mucocele. The importance of the diagnosis, treatment and management of the oral lesions by a dentist during the care of SS patients is emphasized, as the oral manifestations of SS may compromise the patient's quality of life.


Resumo A síndrome de Sjögren (SS) é uma doença autoimune crônica sistêmica que afeta as glândulas lacrimal e salivar. A SS pode se manifestar como SS primária (SSp) ou SS secundária (SSs), a última ocorrendo em conjunto com outra desordem autoimune. Em ambos os casos, os olhos secos e a boca seca afetam a qualidade de vida do paciente. As complicações tardias podem incluir cegueira, destruição dos tecidos dentários, candidíase oral e linfoma. Este artigo relata dois casos de SS, cada um apresentando lesão nodular oral incomum diagnosticada como linfoma MALT reincidente e mucocele. A importância do diagnóstico, tratamento e manejo das lesões orais por um cirurgião-dentista durante o atendimento de pacientes com SS é enfatizada, pois as manifestações orais da SS podem comprometer a qualidade de vida do paciente.


Assuntos
Humanos , Masculino , Feminino , Adulto , Linfoma de Zona Marginal Tipo Células B/diagnóstico , Doenças da Boca/patologia , Neoplasias Bucais/diagnóstico , Mucocele/diagnóstico , Síndrome de Sjogren/patologia , Mucocele/patologia , Qualidade de Vida , Recidiva , Síndrome de Sjogren/complicações
3.
Braz Dent J ; 28(3): 405-412, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29297564

RESUMO

Sjögren's syndrome (SS) is a systemic chronic autoimmune disorder affecting the lacrimal and salivary glands. SS may manifest as primary SS (pSS) or secondary SS (sSS), the latter occurring in the context of another autoimmune disorder. In both cases, the dry eyes and mouth affect the patient's quality of life. Late complications may include blindness, dental tissue destruction, oral candidiasis and lymphoma. This paper reports two cases of SS, each of them presenting unusual oral nodular lesion diagnosed as relapsed MALT lymphoma and mucocele. The importance of the diagnosis, treatment and management of the oral lesions by a dentist during the care of SS patients is emphasized, as the oral manifestations of SS may compromise the patient's quality of life.


Assuntos
Linfoma de Zona Marginal Tipo Células B/diagnóstico , Doenças da Boca/patologia , Neoplasias Bucais/diagnóstico , Mucocele/diagnóstico , Síndrome de Sjogren/patologia , Adulto , Feminino , Humanos , Linfoma de Zona Marginal Tipo Células B/patologia , Masculino , Doenças da Boca/complicações , Mucocele/patologia , Qualidade de Vida , Recidiva , Síndrome de Sjogren/complicações
4.
Braz Dent J ; 27(6): 700-704, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27982182

RESUMO

This study evaluated the efficacy of cleanser solutions on denture biofilm removal by a crossover randomized clinical trial. Thirty two edentulous patients were instructed to brush their dentures (specific brush and liquid soap) three times a day (after breakfast, lunch and dinner) and to soak them (≥ 8 h) in: (C) control -water; (AP): alkaline peroxide; or (SH) 0.5% sodium hypochlorite. Each solution was used for 21 days (three cycles of 7 days). At the end of each cycle, the inner surfaces of maxillary dentures were disclosed (1% neutral red) and photographed (HX1 - Sony). Areas (total and stained biofilm) were measured (Image Tool software) and the percentage of biofilm calculated as the ratio between the area of the biofilm multiplied by 100 and total surface area of the internal base of the denture. Data were compared by means of generalized estimating equation (α=5%) and multiple comparisons (Bonferroni; α=1.67%). Immersion in SH reduced biofilm (%) (8.3 ± 13.3B) compared to C (18.2 ± 14.9A) and AP (18.2 ± 16.6A). The 0.5% sodium hypochlorite solution was the most efficacious for biofilm removal. Alkaline peroxides may not lead to further biofilm removal in patients with adequate denture maintenance habits.


Assuntos
Biofilmes , Dentaduras/microbiologia , Peróxidos/administração & dosagem , Hipoclorito de Sódio/administração & dosagem , Estudos Cross-Over , Feminino , Humanos , Masculino
5.
Braz. dent. j ; 27(6): 700-704, Nov.-Dec. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-828054

RESUMO

Abstract This study evaluated the efficacy of cleanser solutions on denture biofilm removal by a crossover randomized clinical trial. Thirty two edentulous patients were instructed to brush their dentures (specific brush and liquid soap) three times a day (after breakfast, lunch and dinner) and to soak them (≥ 8 h) in: (C) control -water; (AP): alkaline peroxide; or (SH) 0.5% sodium hypochlorite. Each solution was used for 21 days (three cycles of 7 days). At the end of each cycle, the inner surfaces of maxillary dentures were disclosed (1% neutral red) and photographed (HX1 - Sony). Areas (total and stained biofilm) were measured (Image Tool software) and the percentage of biofilm calculated as the ratio between the area of the biofilm multiplied by 100 and total surface area of the internal base of the denture. Data were compared by means of generalized estimating equation (α=5%) and multiple comparisons (Bonferroni; α=1.67%). Immersion in SH reduced biofilm (%) (8.3 ± 13.3B) compared to C (18.2 ± 14.9A) and AP (18.2 ± 16.6A). The 0.5% sodium hypochlorite solution was the most efficacious for biofilm removal. Alkaline peroxides may not lead to further biofilm removal in patients with adequate denture maintenance habits.


Resumo Este estudo avaliou a eficácia de soluções higienizadoras na remoção do biofilme de dentadura por meio de ensaio clínico randomizado cruzado. Trinta e dois pacientes desdentados foram instruídos a escovar suas dentaduras (escova específica e sabão líquido) três vezes ao dia (após café da manhã, almoço e jantar) e imergi-las (≥ 8 horas) em: (C) controle - água; (PA): peróxido alcalino; ou (HS) hipoclorito de sódio a 0,5%. Cada solução foi usada por 21 dias (três ciclos alternados de 7 dias). Ao final de cada ciclo, a superfície interna da dentadura maxilar foi evidenciada (vermelho neutro 1%) e fotografada (HX1- Sony). As áreas (total e corada com biofilme) foram medidas (software Image Tool), e a porcentagem de biofilme calculada como a relação entre a área do biofilme multiplicado por 100 e área da superfície total da base interna da dentadura. Os dados foram comparados por meio de equações de estimação generalizadas (α=5%) e comparações múltiplas (Bonferroni - α=1,67%). A imersão em HS reduziu o biofilme (%) (8,3 ± 13,3B) em comparação com C (18,2 ± 14,9A) e PA (18,2 ± 16,6A). A solução de hipoclorito de sódio a 0,5% foi a mais eficaz na remoção do biofilme. Peróxidos alcalinos podem não levar a maior remoção do biofilme em pacientes com hábitos adequados de manutenção de dentadura.


Assuntos
Humanos , Masculino , Feminino , Biofilmes , Dentaduras/microbiologia , Peróxidos/administração & dosagem , Hipoclorito de Sódio/administração & dosagem , Estudos Cross-Over
6.
J. appl. oral sci ; 23(6): 637-642, Nov.-Dec. 2015. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-769824

RESUMO

ABSTRACT To preserve oral health and to maintain the prosthetic devices, it is important not only to improve the properties of commonly known hygiene products, but also to investigate new materials with antimicrobial action. Objectives This study evaluated the antimicrobial activity of sodium hypochlorite (0.25% and 0.50%) and 10% Ricinus communis’ solutions against specific microorganisms. Material and Methods Sixty four maxillary complete denture wearers were instructed to brush their dentures three times a day and to soak them (20 min/day) in the solutions: SH1: 0.25% sodium hypochlorite; SH2: 0.5% sodium hypochlorite; RC: 10% R. communis oil; and C: 0.85% saline (control). The solutions were used for 7 days in a randomized sequence. Following each period of use, there was a 1-week washout period. Antimicrobial activity was determined by Colony Forming Units (CFU) counts of Streptococcus mutans, Candida spp., and gram-negative microorganisms. For collecting biofilm, the internal surface of maxillary dentures was brushed with saline solution, and biofilm suspension obtained. After dilutions (100 - 10-3), aliquots were seeded in Mitis salivarius, CHROMagar Candida®, and MacConkey agar for detecting S. mutans, Candida spp., or gram-negative microorganisms, respectively. After incubation, colonies were counted, and CFU/mL values were calculated. Then, transformation - log10 (CFU+1) - data were analyzed using the Friedman test (α=0.05). Results showed significant differences between the solutions (p<0.001). Results All three solutions showed antimicrobial activity against S. mutans. Against Candida spp., RC and SH1 solutions showed similar effect while SH2 showed superior activity. SH1 and SH2 solutions showed antimicrobial action against gram-negative microorganisms. The Candida species most frequently isolated was C. albicans, followed by C. tropicalis and C. glabrata. Conclusions The 0.5% sodium hypochlorite solution was the most effective and might be used to control denture biofilm. C. albicans was the most frequently isolated Candida sp.


Assuntos
Humanos , Masculino , Feminino , Idoso , Anti-Infecciosos Locais/farmacologia , Biofilmes/efeitos dos fármacos , Higienizadores de Dentadura/farmacologia , Prótese Total/microbiologia , Ricinus/química , Hipoclorito de Sódio/farmacologia , Candida/efeitos dos fármacos , Candida/isolamento & purificação , Óleo de Rícino/farmacologia , Contagem de Colônia Microbiana , Bactérias Gram-Negativas/efeitos dos fármacos , Bactérias Gram-Negativas/isolamento & purificação , Estatísticas não Paramétricas , Streptococcus mutans/efeitos dos fármacos , Streptococcus mutans/isolamento & purificação , Fatores de Tempo
7.
Braz. j. oral sci ; 14(3): 219-223, July-Sept. 2015. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-770526

RESUMO

Abstract Aim: To evaluate the sorption, solubility and color change in two lining materials after 120 days of immersion in either sodium perborate or artificial saliva. Methods: Thirty disk-shaped specimens (15×3 mm) of each material, Mucopren(r) soft (MS) and Elite(r) soft (ES) were manufactured and divided into two groups. The specimens in the control group (CG, n=15) were stored in artificial saliva at 37 °C. The specimens in the experimental group (EG, n=15) were stored in artificial saliva at 37 °C and immersed in sodium perborate daily for 5 min. The analysis of sorption and solubility was based on the initial dry weight and on the wet and dry weights after immersion. The color was assessed with a portable spectrophotometer and the NBS system. ANOVA and Tukey test (p<0.05) were used to analyze color and sorption. The solubility was analyzed by KruskalWallis test (p<0.05). Results: Sorption was higher in the EG group (0.31±0.08) than in the control group (0.26±0.05), and higher in Elite(r) soft relining (0.34±0.07) than in Mucopren(r) soft (0.23±0.06). There was no interaction between the factors. Elite(r) Soft presented a higher solubility when immersed in artificial saliva (CG: 0.16±0.07 and EG: 0.13±0.06; p=0.00). Mucopren(r) soft showed no solubility in either treatment. Regarding the color changes, there was a significant difference between the groups (CG: 9.2±1.2 and EG: 9.9±1.2; p=0.025) but not between the materials (Mucopren(r) soft: 9.4±1.3 and Elite(r)soft: 9.7±1.0; p=0.34). Using the NBS system, we verified that both materials presented a high color change. Conclusions: The daily use of sodium perborate promoted changes in the liners' sorption and color. Elite(r) soft relining was more prone to changes than Mucopren(r) soft.


Assuntos
Higiene , Fenômenos Físicos , Prótese Total , Reembasadores de Dentadura
8.
J Appl Oral Sci ; 23(6): 637-42, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26814466

RESUMO

UNLABELLED: To preserve oral health and to maintain the prosthetic devices, it is important not only to improve the properties of commonly known hygiene products, but also to investigate new materials with antimicrobial action. Objectives This study evaluated the antimicrobial activity of sodium hypochlorite (0.25% and 0.50%) and 10% Ricinus communis' solutions against specific microorganisms. MATERIAL AND METHODS: Sixty four maxillary complete denture wearers were instructed to brush their dentures three times a day and to soak them (20 min/day) in the solutions: SH1: 0.25% sodium hypochlorite; SH2: 0.5% sodium hypochlorite; RC: 10% R. communis oil; and C: 0.85% saline (control). The solutions were used for 7 days in a randomized sequence. Following each period of use, there was a 1-week washout period. Antimicrobial activity was determined by Colony Forming Units (CFU) counts of Streptococcus mutans, Candida spp., and gram-negative microorganisms. For collecting biofilm, the internal surface of maxillary dentures was brushed with saline solution, and biofilm suspension obtained. After dilutions (100 - 10-3), aliquots were seeded in Mitis salivarius, CHROMagar Candida, and MacConkey agar for detecting S. mutans, Candida spp., or gram-negative microorganisms, respectively. After incubation, colonies were counted, and CFU/mL values were calculated. Then, transformation - log10 (CFU+1) - data were analyzed using the Friedman test (α=0.05). Results showed significant differences between the solutions (p<0.001). RESULTS: All three solutions showed antimicrobial activity against S. mutans. Against Candida spp., RC and SH1 solutions showed similar effect while SH2 showed superior activity. SH1 and SH2 solutions showed antimicrobial action against gram-negative microorganisms. The Candida species most frequently isolated was C. albicans, followed by C. tropicalis and C. glabrata. CONCLUSIONS: The 0.5% sodium hypochlorite solution was the most effective and might be used to control denture biofilm. C. albicans was the most frequently isolated Candida sp.


Assuntos
Anti-Infecciosos Locais/farmacologia , Biofilmes/efeitos dos fármacos , Higienizadores de Dentadura/farmacologia , Prótese Total/microbiologia , Ricinus/química , Hipoclorito de Sódio/farmacologia , Idoso , Candida/efeitos dos fármacos , Candida/isolamento & purificação , Óleo de Rícino/farmacologia , Contagem de Colônia Microbiana , Feminino , Bactérias Gram-Negativas/efeitos dos fármacos , Bactérias Gram-Negativas/isolamento & purificação , Humanos , Masculino , Estatísticas não Paramétricas , Streptococcus mutans/efeitos dos fármacos , Streptococcus mutans/isolamento & purificação , Fatores de Tempo
9.
J Appl Oral Sci ; 22(5): 442-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25466477

RESUMO

UNLABELLED: The adhesion of biofilm on dental prostheses is a prerequisite for the occurrence of oral diseases. OBJECTIVE: To assess the antimicrobial activity and the mechanical properties of an acrylic resin embedded with nanostructured silver vanadate (ß-AgVO3). MATERIAL AND METHODS: The minimum inhibitory concentration (MIC) of ß-AgVO3 was studied in relation to the species Staphylococcus aureus ATCC 25923, Streptococcus mutans ATCC 25175, Pseudomonas aeruginosa ATCC 27853, and Candida albicans ATCC 10231. The halo zone of inhibition method was performed in triplicate to determine the inhibitory effect of the modified self-curing acrylic resin Dencor Lay-Clássico. The surface hardness and compressive strength were examined. The specimens were prepared according to the percentage of ß-AgVO3 (0%-control, 0.5%, 1%, 2.5%, 5%, and 10%), with a sample size of 9x2 mm for surface hardness and antimicrobial activity tests, and 8x4 mm for the compression test. The values of the microbiologic analysis were compared and evaluated using the Kruskal-Wallis test (α=0.05); the mechanical analysis used the Shapiro-Wilk's tests, Levene's test, ANOVA (one-way), and Tukey's test (α=0.05). RESULTS: The addition of 10% ß-AgVO3 promoted antimicrobial activity against all strains. The antimicrobial effect was observed at a minimum concentration of 1% for P. aeruginosa, 2.5% for S. aureus, 5% for C. albicans, and 10% for S. mutans. Surface hardness and compressive strength increased significantly with the addition of 0.5% ß-AgVO3 (p<0.05). Higher rates of the nanomaterial did not alter the mechanical properties of the resin in comparison with the control group (p>0.05). CONCLUSIONS: The incorporation of ß-AgVO3 has the potential to promote antimicrobial activity in the acrylic resin. At reduced rates, it improves the mechanical properties, and, at higher rates, it does not promote changes in the control.


Assuntos
Resinas Acrílicas/farmacologia , Anti-Infecciosos/farmacologia , Prata/farmacologia , Vanadatos/farmacologia , Resinas Acrílicas/química , Análise de Variância , Anti-Infecciosos/química , Candida albicans/efeitos dos fármacos , Candida albicans/crescimento & desenvolvimento , Força Compressiva , Prótese Dentária/microbiologia , Testes de Dureza , Teste de Materiais , Testes de Sensibilidade Microbiana , Pseudomonas aeruginosa/efeitos dos fármacos , Pseudomonas aeruginosa/crescimento & desenvolvimento , Reprodutibilidade dos Testes , Prata/química , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/crescimento & desenvolvimento , Estatísticas não Paramétricas , Streptococcus mutans/efeitos dos fármacos , Streptococcus mutans/crescimento & desenvolvimento , Propriedades de Superfície , Fatores de Tempo , Vanadatos/química
10.
J. appl. oral sci ; 22(5): 442-449, Sep-Oct/2014. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-729843

RESUMO

The adhesion of biofilm on dental prostheses is a prerequisite for the occurrence of oral diseases. Objective: To assess the antimicrobial activity and the mechanical properties of an acrylic resin embedded with nanostructured silver vanadate (β-AgVO3). Material and Methods: The minimum inhibitory concentration (MIC) of β-AgVO3 was studied in relation to the species Staphylococcus aureus ATCC 25923, Streptococcus mutans ATCC 25175, Pseudomonas aeruginosa ATCC 27853, and Candida albicans ATCC 10231. The halo zone of inhibition method was performed in triplicate to determine the inhibitory effect of the modified self-curing acrylic resin Dencor Lay - Clássico®. The surface hardness and compressive strength were examined. The specimens were prepared according to the percentage of β-AgVO3 (0%-control, 0.5%, 1%, 2.5%, 5%, and 10%), with a sample size of 9x2 mm for surface hardness and antimicrobial activity tests, and 8x4 mm for the compression test. The values of the microbiologic analysis were compared and evaluated using the Kruskal-Wallis test (α=0.05); the mechanical analysis used the Shapiro-Wilk's tests, Levene's test, ANOVA (one-way), and Tukey's test (α=0.05). Results: The addition of 10% β-AgVO3 promoted antimicrobial activity against all strains. The antimicrobial effect was observed at a minimum concentration of 1% for P. aeruginosa, 2.5% for S. aureus, 5% for C. albicans, and 10% for S. mutans. Surface hardness and compressive strength increased significantly with the addition of 0.5% β-AgVO3 (p<0.05). Higher rates of the nanomaterial did not alter the mechanical properties of the resin in comparison with the control group (p>0.05). Conclusions: The incorporation of β-AgVO3 has the potential to promote antimicrobial activity in the acrylic resin. At reduced rates, it improves the mechanical properties, and, at higher rates, it does not promote changes in the control. .


Assuntos
Resinas Acrílicas/farmacologia , Anti-Infecciosos/farmacologia , Prata/farmacologia , Vanadatos/farmacologia , Resinas Acrílicas/química , Análise de Variância , Anti-Infecciosos/química , Candida albicans/efeitos dos fármacos , Candida albicans/crescimento & desenvolvimento , Força Compressiva , Prótese Dentária/microbiologia , Testes de Dureza , Teste de Materiais , Testes de Sensibilidade Microbiana , Pseudomonas aeruginosa/efeitos dos fármacos , Pseudomonas aeruginosa/crescimento & desenvolvimento , Reprodutibilidade dos Testes , Prata/química , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/crescimento & desenvolvimento , Estatísticas não Paramétricas , Streptococcus mutans/efeitos dos fármacos , Streptococcus mutans/crescimento & desenvolvimento , Propriedades de Superfície , Fatores de Tempo , Vanadatos/química
11.
Braz Oral Res ; 282014.
Artigo em Inglês | MEDLINE | ID: mdl-24918370

RESUMO

This study evaluated the effect of cleanser solutions on the color of heat-polymerized acrylic resin (HPAR) and on the brightness of dental alloys with 180 immersion trials. Disk-shaped specimens were made with I) commercially pure titanium, II) nickel-chromium-molybdenum-titanium, III) nickel-chromium molybdenum, and IV) nickel-chromium-molybdenum beryllium. Each cast disk was invested in the flasks, incorporating the metal disk into the HPAR. The specimens (n=5) were then immersed in solutions containing: 0.05% sodium hypochlorite, 0.12% chlorhexidine digluconate, 0.500 mg cetylpyridinium chloride, a citric acid tablet, one of two different sodium perborate/enzyme tablets, and water. The color measurements (∆E) of the HPAR were determined by a colorimeter in accordance with the National Bureau of Standards. The surface brightness of the metal was visually examined for the presence of tarnish. The results (ANOVA; Tukey test-α=0.05) show that there was a significant difference between the groups (p<0.001) but not among the solutions (p=0.273). The highest mean was obtained for group III (5.06), followed by group II (2.14). The lowest averages were obtained for groups I (1.33) and IV (1.35). The color changes in groups I, II and IV were slight but noticeable, and the color change was considerable for group III. The visual analysis showed that 0.05% sodium hypochlorite caused metallic brightness changes in groups II and IV. It can be concluded that the agents had the same effect on the color of the resin and that the metallic alloys are not resistant to the action of 0.05% sodium hypochlorite.


Assuntos
Resinas Acrílicas/química , Ligas de Cromo/química , Higienizadores de Dentadura/química , Pigmentação em Prótese , Titânio/química , Ligas/química , Análise de Variância , Cor , Desinfetantes de Equipamento Odontológico/química , Humanos , Imersão , Teste de Materiais , Polimerização , Distribuição Aleatória , Hipoclorito de Sódio/química , Propriedades de Superfície , Fatores de Tempo
12.
RGO (Porto Alegre) ; 60(4): 449-454, out.-dez. 2012. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-874828

RESUMO

Objective: This study evaluated the change in toothbrush bristles after brushing with water and four dentifrices, one for natural teeth (Sorriso, Colgate-Palmolive Ind e Com. Ltda., Osasco, Brazil) and three for dentures: Corega (GSK - GlaxoSmithKline, Brasil Ltda., Rio de Janeiro, Brazil), Experimental 1 (Zonil) Experiment 2 (Chloramine T). Methods: Soft brushes were used with 26 clumps of bristles with 0.25 mm in diameter and 10 mm high. Brushing was performed on a Pepsodent machine where the toothbrushes and associated dentifrices brushed acrylic specimens (Plex-glass). The brushing time was 50 minutes (one year/17,800 cycles). Ten toothbrush bristles per group were removed. A group of ten unused bristles represented the control group. The bristles were placed on a Plex-glass dish so that they were all in the same plane. The diameter measurement was performed using a profilometer with a precision of tenths of millimeters (0.01 mm) to within 0.02 mm of the tip of the bristle. Ten values were obtained for each combination (toothbrush and toothpaste) tested. Results: Data analysis was performed using Anova Test (P <0.05). The results indicated that only the Sorriso group (Colgate-Palmolive Ind e Com. Ltda., Osasco, Brazil) (0.15 ± 0.02) compared with the control group (0.2 ± 0.02) was statistically significant (P = 0.0117), while the values of the other groups (Water: 0.18 ± 0.02; Corega (GSK - GlaxoSmithKline, Brasil Ltda., Rio de Janeiro, Brazil): 0.17 ± 0.2; Experimental 1: 0.16 ± 0.02; Experimental 2: 0.16 ± 0.02) showed no significant change. Conclusion: The Sorriso toothpaste (Colgate-Palmolive Ind e Com. Ltda., Osasco, Brazil), suitable for natural teeth, caused the biggest change on the tips of toothbrush bristles.


Objetivo: Avaliar a alteração nas cerdas de escovas dentais após escovação com água e quatro dentifrícios, sendo um para dentes naturais (Sorriso, Colgate-Palmolive Ind e Com. Ltda., Osasco, Brasil) e três para próteses totais: Corega (GSK - GlaxoSmithKline, Brasil Ltda., Rio de Janeiro, Brasil), Experimental 1 (Zonil), Experimental 2 (Cloramina T).Métodos: Foram utilizadas escovas macias com 26 tufos de cerdas de 0,25mm de diâmetro e 10 mm de altura. A escovação foi realizada em máquina do tipo Pepsodent, na qual as escovas associadas às suspensões dos dentifrícios escovaram corpos-de-prova de resina acrílica (Plex-glass) por um período de 50 minutos, simulando um ano (17800 ciclos). Foram removidas dez cerdas das escovas por grupo. Um grupo com dez cerdas não utilizadas representou o controle. As cerdas foram posicionadas em uma placa de Plex-glass de forma que ficassem todas em um mesmo plano. A aferição do diâmetro foi realizada em perfilômetro com precisão de décimos de milímetros (0,01 mm) a 0,02 mm da ponta da cerda. Foram obtidos dez valores para cada combinação (escova e dentifrício) testada. Resultados: A análise dos dados foi realizada por meio dos Testes ANOVA (p<0,05). Os resultados indicaram que apenas o grupo Sorriso (Colgate-Palmolive Ind e Com. Ltda., Osasco, Brasil) (0,15±0,02) quando comparado com o grupo controle (0,2±0,02) apresentou significância estatística (p=0,0117), enquanto os outros grupos (água: 0,18±0,02; Corega (GSK - GlaxoSmithKline, Brasil Ltda., Rio de Janeiro, Brasil): 0,17±0,2; Experimental 1: 0,16±0,02; Experimental 2: 0,16±0,02) não apresentaram valores de alteração significantes.Conclusão: O dentifrício Sorriso (Colgate-Palmolive Ind e Com. Ltda., Osasco, Brasil), indicado para dentes naturais, foi o que causou a maior alteração nas pontas das cerdas das escovas.


Assuntos
Dentifrícios , Escovação Dentária , Prótese Total
13.
Braz Dent J ; 23(1): 15-21, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22460309

RESUMO

This study evaluated Knoop hardness, surface roughness and color alteration of artificial teeth for dentures after immersion in water, 1% sodium hypochlorite and an experimental solution of 2% Ricinus communis (RC). Thirty specimens of Vipi, Biolux and Trilux were analyzed. Tests of Knoop hardness, surface roughness and color alteration were conducted immediately after specimen preparation (T0) and after two immersion protocols for 15 days (ΔT(15)) and 183 days (ΔT(183)). Data variation (ΔT) were subjected to ANOVA and Tukey's test (p<0.05). At ΔT(15), Vipi presented hardness increase and Biolux presented the highest variation (p=0.01). RC caused the highest increase in hardness (p=0) and the lowest increase (p=0.005) in roughness. Biolux presented the lowest color alteration (p =0). At ΔT(183), Trilux underwent the highest hardness variation (p=0). Biolux presented an increase in roughness (p=0). There was no significant differences in color alteration among the artificial teeth (p=0.06) and among solutions (p=0.08) after 183 days of immersion. All solutions (distilled water, 1% sodium hypochlorite and 2% RC) caused alterations on the analyzed properties. Both immersion protocols caused alterations on the analyzed properties.


Assuntos
Dentaduras , Higiene Bucal/métodos , Preparações de Plantas/farmacologia , Ricinus , Dente Artificial , Resinas Acrílicas , Humanos , Teste de Materiais , Hipoclorito de Sódio/farmacologia
14.
Braz. dent. j ; 23(1): 15-21, 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-617999

RESUMO

This study evaluated Knoop hardness, surface roughness and color alteration of artificial teeth for dentures after immersion in water, 1 percent sodium hypochlorite and an experimental solution of 2 percent Ricinus communis (RC). Thirty specimens of Vipi, Biolux and Trilux were analyzed. Tests of Knoop hardness, surface roughness and color alteration were conducted immediately after specimen preparation (T0) and after two immersion protocols for 15 days (ΔT15) and 183 days (ΔT183). Data variation (ΔT) were subjected to ANOVA and Tukey's test (p<0.05). At ΔT15, Vipi presented hardness increase and Biolux presented the highest variation (p=0.01). RC caused the highest increase in hardness (p=0) and the lowest increase (p=0.005) in roughness. Biolux presented the lowest color alteration (p =0). At ΔT183, Trilux underwent the highest hardness variation (p=0). Biolux presented an increase in roughness (p=0). There was no significant differences in color alteration among the artificial teeth (p=0.06) and among solutions (p=0.08) after 183 days of immersion. All solutions (distilled water, 1 percent sodium hypochlorite and 2 percent RC) caused alterations on the analyzed properties. Both immersion protocols caused alterations on the analyzed properties.


Este estudo avaliou a dureza Knoop, rugosidade e alteração de cor de dentes artificiais após imersão em água, hipoclorito de sódio 1 por cento e solução de Ricinus communis 2 por cento (RC). Trinta espécimes de dentes das marcas Vipi, Biolux e Trilux foram analisados. Os testes de dureza, rugosidade e alteração de cor foram realizados após a obtenção dos espécimes (T0) e após dois protocolos de imersão nas soluções por 15 dias (Δ15) e 183 dias (Δ183). A variação dos dados (ΔT) foi submetida à ANOVA e teste de Tukey (p<0,05). Em ΔT15, Vipi apresentou aumento da dureza e Biolux, a maior variação (p =0,01). RC causou o maior aumento na dureza (p=0). RC causou o menor aumento na rugosidade (p=0,005). Biolux apresentou a menor alteração de cor (p=0). Em ΔT183, Trilux apresentou a maior variação na dureza. (p=0). Biolux apresentou aumento na rugosidade (p=0). Não houve diferença significante na alteração de cor entre dentes (p=0,06) e entre soluções (p=0,08) após 183 dias de imersão. Todas as soluções (água destilada, hipoclorito de sódio 1 por cento e RC) causaram alterações nas propriedades analisadas. Ambos os protocolos de imersão causaram alterações nas propriedades analisadas.


Assuntos
Humanos , Dentaduras , Higiene Bucal/métodos , Preparações de Plantas/farmacologia , Ricinus , Dente Artificial , Resinas Acrílicas , Teste de Materiais , Hipoclorito de Sódio/farmacologia
15.
Rev. odontol. UNESP (Online) ; 40(3): 125-130, maio-jun. 2011. tab, ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-614434

RESUMO

Este estudo avaliou a alteração de cor do silicone Ortho Pauher, tendo como padrão ouro o silicone MDX 4 - 4210, frente ao envelhecimento e à pigmentação. Foram obtidos sessenta espécimes para cada material, os quais receberam pigmentação intrínseca ou pigmentação intrínseca e extrínseca. Como pigmento, foi utilizado pó de maquiagem. Os espécimes foram distribuídos aleatoriamente em três grupos e submetidos ao envelhecimento ou por termociclagem, luz ultravioleta ou para compor o grupo controle. Como controle, espécimes foram mantidos em um recipiente hermeticamente fechado na ausência de luz. O envelhecimento simulou um período de uso de 12 meses. Os testes ANOVA e Tukey (p < 0,05) indicaram diferença significante entre o grupo controle e osgrupos envelhecidos por termociclagem e luz ultravioleta, sendo que estes se mostraram iguais. Em relação aos materiais, não houve diferença entre eles. Houve diferença entre as pigmentações. Na interação, o Ortho Pauher sofreu maior variação de cor causada pela luz ultravioleta, enquanto o MDX, pela termociclagem. Comparando-seos materiais com pigmentação intrínseca, nos três grupos de envelhecimento houve diferença entre o controle e a luz ultravioleta, sendo que a maior alteração foi encontrada para o Ortho Pauher. Para os materiais com pigmentação intrínseca e extrínseca, houve diferença nos três grupos de envelhecimento, com maior variação para o MDX.Notam-se comportamentos distintos dos materiais em função da pigmentação e do envelhecimento, devendo-se considerar a associação entre material, tipo de pigmento e tipo de exposição para que se faça a indicação clínica corretamente, podendo-se considerar o Ortho Pauher na confecção de próteses maxilofaciais.


This study evaluated the color change of the silicone Ortho Pauher, with the standard gold silicone MDX 4 - 4210, facing the aging and pigmentation. Sixty specimens were obtained for each material, which received intrinsic or intrinsic and extrinsic pigmentation. Powder makeup was used as pigment. The specimens were randomly dividedinto three groups and subjected to aging or thermal cycling, ultraviolet light or to compose the control group. As control, specimens were kept in an airtight container in the absence of light. Aging simulated a period of 12 months. ANOVA and Tukey tests (p < 0.05) indicated a significant difference between control group and the groups aging by thermal cycling and ultraviolet light, which were equal. In relation to materials, there was no difference between them. There was a difference between pigmentation. In the interaction, Ortho Pauher suffered major color changescaused by ultraviolet light, while the MDX, by thermocycling. Comparing the materials with intrinsic pigmentation, the aging in the three groups was difference between control and ultraviolet light, and the greatest change was found for the Ortho Pauher. For materials with intrinsic pigmentation and extrinsic, there were differences between the three groups of the aging, with greater variation for the MDX. Note the different behavior of materials as a function of pigmentation and aging, one should considered the relationship between material, pigment type and type ofexposure in order to do properly the clinical indication, and may be considered silicone Ortho Pauher in making of the maxillofacial prosthesis.


Assuntos
Silicones , Raios Ultravioleta , Envelhecimento , Pigmentação , Análise de Variância , Cor , Prótese Maxilofacial
16.
Braz Dent J ; 21(3): 247-52, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21203709

RESUMO

In this study, a questionnaire was applied to patients from Ribeirão Preto Dental School, University of São Paulo, Brazil, to evaluate the hygiene methods and habits concerning the use of complete dentures, the age of dentures, and whether patients have been instructed on how to clean their dentures. The mean age of patients was 63.35 years, and most of them were females (82.08%). The results showed that 62.26% of the respondents had been using the same maxillary complete denture for more than 5 years, and 49.06% used the same mandible complete denture for more than 5 years. Of the patients interviewed, 58.49% slept with the dentures. Mechanical brushing was the most used cleaning method by the patients (100%), using water, dentifrice and toothbrush (84.91%). Most patients (51.89%) reported never having been instructed by their dentists as to how to clean their dentures. Based on the limitations of this study, it was concluded that the patients interviewed had limited knowledge about prosthetic hygiene and oral care. The method more used by patients was the mechanical method of brushing, most patients used the same complete dentures for more than 5 years and slept with the dentures.


Assuntos
Higienizadores de Dentadura , Prótese Total Inferior , Prótese Total Superior , Comportamentos Relacionados com a Saúde , Higiene Bucal , Idoso , Idoso de 80 Anos ou mais , Inquéritos de Saúde Bucal , Feminino , Hábitos , Humanos , Arcada Edêntula , Masculino , Pessoa de Meia-Idade , Educação de Pacientes como Assunto , Fatores de Tempo
17.
Braz. dent. j ; 21(3): 247-252, 2010. ilus, tab
Artigo em Inglês | LILACS | ID: lil-556826

RESUMO

In this study, a questionnaire was applied to patients from Ribeirão Preto Dental School, University of São Paulo, Brazil, to evaluate the hygiene methods and habits concerning the use of complete dentures, the age of dentures, and whether patients have been instructed on how to clean their dentures. The mean age of patients was 63.35 years, and most of them were females (82.08 percent). The results showed that 62.26 percent of the respondents had been using the same maxillary complete denture for more than 5 years, and 49.06 percent used the same mandible complete denture for more than 5 years. Of the patients interviewed, 58.49 percent slept with the dentures. Mechanical brushing was the most used cleaning method by the patients (100 percent), using water, dentifrice and toothbrush (84.91 percent). Most patients (51.89 percent) reported never having been instructed by their dentists as to how to clean their dentures. Based on the limitations of this study, it was concluded that the patients interviewed had limited knowledge about prosthetic hygiene and oral care. The method more used by patients was the mechanical method of brushing, most patients used the same complete dentures for more than 5 years and slept with the dentures.


Foi realizada uma pesquisa na Faculdade de Odontologia de Ribeirão Preto - Universidade de São Paulo, por meio da aplicação de questionário, para avaliar os métodos de higiene e hábitos referentes ao uso de prótese total, idade das próteses, e se os pacientes têm sido instruídos em como limpar suas próteses. A idade média dos pacientes estudados foi 63,35 anos, a maioria (82,08 por cento) do sexo feminino. Os resultados mostraram que 62,26 por cento dos entrevistados usavam a mesma prótese total superior há mais de 5 anos, e 49,06 por cento a mesma prótese total inferior. Dos pacientes entrevistados, 58,49 por cento dormiam com as próteses. O método mais utilizado pelos pacientes foi o método mecânico de escovação (100 por cento dos pacientes), utilizando água, pasta e escova de dente (84,91 por cento). A maioria dos pacientes (51,89 por cento) relatou nunca ter sido orientado pelos dentistas de como higienizar as próteses. Baseado nas limitações deste estudo, concluiu-se que os pacientes entrevistados tinham conhecimento limitado sobre higiene protética e cuidados bucais. O método de higiene mais utilizado foi a escovação da prótese, a maioria dos pacientes usavam a mesma prótese total há mais de cinco anos e dormiam com as próteses.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Higienizadores de Dentadura , Prótese Total Inferior , Prótese Total Superior , Comportamentos Relacionados com a Saúde , Higiene Bucal , Inquéritos de Saúde Bucal , Hábitos , Arcada Edêntula , Educação de Pacientes como Assunto , Fatores de Tempo
18.
Rev. Odontol. Araçatuba (Impr.) ; 28(3): 9-15, set.-dez. 2007. tab, ilus
Artigo em Português | BBO - Odontologia | ID: biblio-856809

RESUMO

O objetivo deste trabalho foi comparar os níveis de biofilme em superfícies internas e externas de próteses totais, empregando fotografia e método computadorizado de quantificação. Quarenta usuários de próteses totais superiores escovaram suas próteses 3 vezes ao dia após as refeições com um dentifrício convencional (Sorriso, Colgate) e escova macia (Johnson & Johnson). O período experimental compreendeu 30 dias divididos em 3 visitas (0, 15 e 30 dias). Em cada visita, as superfícies internas (assentamento basal) e externas (flanco bucal direito) das próteses foram evidenciadas e fotografadas. A superfície interna foi fotografada em ângulos de 90° (fotografia A) e 45° (fotografia B) e a superfície externa, em ângulo de 90º (fotografia C). Para a quantificação do biofilme, as fotografias foram transferidas para um computador (Intel S478 P4 2.8), processadas (Adobe Photoshop 5.5) e as medidas da área total e da área corada contendo biofilme, foram realizadas com auxílio do software Image Tool. O Teste de Wilcoxon (P<.05) mostrou diferença significante entre a superfície interna em ângulo de 45º (fotografia B) e a superfície externa (fotografia C), as quais apresentaram os mais altos e mais baixos níveis de biofilme, respectivamente. Como as condições encontradas na superfície interna da prótese total superior em relação aos níveis de biofilme são consideradas como aquelas que refletem as condições da higiene oral de pacientes usuários de próteses totais, os resultados mostraram a importância de avaliar os níveis de biofilme nessa superfície, utilizando fotografia em ângulo de 45°


Profissionals that deal with dental prosthesis been in experience a mixt of ideal and frustration in relation to the possibility of using resilient bases in prosthesis presenting support on mucosa, since those bases, when properly indicated and used, promote interesting final results regarding patient’s comfort. Nevertheless, in a short time, one can experience frustration when the professional is faced with deteriorated materials, as well as debonding of bases from the prosthesis made with heat-cured acrylic resin, and the fairly understandable disastifaction on the part of the patient. Clinical efficiency of those materials depends on knowing their characteristics, indications and properties, which will be discussed in this article


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Escovação Dentária , Higiene Bucal , Placa Dentária , Prótese Dentária , Prótese Total
19.
Rev. odontol. UNESP ; 35(2): 125-131, abr.-jun. 2006. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-512559

RESUMO

O objetivo desse trabalho foi realizar um estudo longitudinal a respeito dosmateriais e métodos de higiene utilizados por usuários de próteses totais, bem como avaliar ograu de instruções dos mesmos. O levantamento dos dados foi realizado por meio da aplicaçãode questionário e posterior tabulação dos dados. Foram entrevistados 98 usuários de prótesestotais no ano de 1989 e 100, no ano de 2004 atendidos na Faculdade de Odontologia de RibeirãoPreto-USP. Os resultados foram analisados por meio da comparação dos dados e pelo Teste dasProporções. Em 1989, 93,87% dos entrevistados relataram utilizar escova dental e dentifrício parahigiene de próteses totais. No ano de 2004, 95% dos usuários relataram utilizar o mesmo métodode higiene. Quanto ao grau de instrução, mais de 80% dos pacientes não receberam orientaçãoquanto à higienização ou quanto à necessidade de visita periódica ao cirurgião-dentista no ano de1989, mas em 2004 pôde-se notar que houve uma melhora significativa nesse quadro, uma vezque 52% dos pacientes não receberam orientação quanto à higienização e 77% não receberamorientação quanto à visita periódica ao cirurgião-dentista. Por meio deste estudo verificou-se queo método mais utilizado consiste no método mecânico, uma vez que são aqueles regularmenteencontrados no mercado, porém, estes não são específicos para higienização de próteses totais.Embora o grau de instrução tenha melhorado ao longo dos anos, a higiene oral de usuários deprótese total ainda é precária, havendo necessidade de maior atenção ao idoso, não somente porparte do cirurgião-dentista, mas também de indústrias de produtos de higiene oral, para que osdesdentados totais tenham acesso aos produtos específicos para este fim, podendo assim, controlarde forma adequada sua saúde oral.


The goal of this work was to accomplish a longitudinal study concerning aboutof the materials and methods of hygiene used by complete dentures users, as well as to evaluatethe instructions degree of the same. The rising of the data was accomplished by means of thequestionnaire and posterior table application of the data. They were interviewed 98 completedentures users in year of 1989 and 100, in year of 2004 attended in to Odontology Faculty ofRibeirão Preto. The results were analyzed by means of the comparison of the data and by theProportions Test. In 1989, 93.87% of the interviewees related use dental brush and toothpastefor complete denture hygiene. In year of 2004, 95% of the users related use the same hygienemethod. Regarding the instruction degree, more than 80% of the patients did not receive orientationregarding cleansers or regarding the need to periodic visit to the surgeon-dentist in year of 1989,but in 2004 could notice that there was a significant improvement in this picture, once that 52% of the patients did not receive orientation regarding cleansers and 77% did not receive orientationregarding the periodic visit to the surgeon-dentist. For half of this study it verified that the usedmethod consists in mechanical method, once that are those methods are not regularly found in themarket, however, these are not specific for denture complete hygiene. Although the instructiondegree has improved along years, the users’ oral complete denture hygiene is precarious, therebeing need to larger attention to the senior, not only by the surgeon-dentist, but also of productsindustries of oral hygiene, so that the total toothless have access to the specific products for thisend, could this way, control of adequate your form oral health.


Assuntos
Higiene , Prótese Total
20.
Braz. dent. j ; 16(2): 135-139, maio-ago. 2005. ilus
Artigo em Inglês | LILACS | ID: lil-413413

RESUMO

Este trabalho descreve o uso de um cabo funcional removível em resina acrílica que pode ser facilmente adaptado a moldeiras individuais para fornecer um bom registro da zona de selamento periférico. Este dispositivo pode ser indicado para moldagem final em prótese total utilizando a técnica de movimentação muscular realizada pelo paciente. Em moldeiras superiores, o cabo é fixado na linha mediana com resina acrílica, enquanto nas inferiores, a parte central do cabo é desmontável permitindo sua remoção antes da moldagem dos bordos laterais. O cabo removível é passível de sucção pelo paciente e permite que a língua seja movimentada livremente. A moldagem final é realizada em duas fases: moldagem da zona de selado periférico (godiva de baixa fusão) e da superfície de suporte (pasta de óxido de zinco e eugenol). Todos os registros musculares da zona de selado periférico são obtidos por meio de movimentação muscular realizada pelo paciente (sucção do cabo e movimentação lingual). O cabo funcional é reutilizável, permite um bom registro da zona de selado periférico (bordas teciduais) e pode ser adaptado a moldeiras individuais de resina acrílica devido à sua facilidade e simplicidade de uso.


Assuntos
Humanos , Técnica de Moldagem Odontológica , Planejamento de Dentadura , Prótese Total , Resinas Acrílicas , Materiais para Moldagem Odontológica/química , Técnica de Moldagem Odontológica/instrumentação , Desenho de Equipamento , Registro da Relação Maxilomandibular , Movimento , Músculos da Mastigação/fisiologia , Propriedades de Superfície , Língua/fisiologia , Cimento de Óxido de Zinco e Eugenol/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...